X
This eshop uses cookies to provide services, customize your ads, and analyze your traffic. More information. Accept all cookies Personalize
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!
DB/DC Chimney Sweep Bench Bracket | Ideal for Concrete and Ceramic Tiles | Best Price!

DB/DC chimney bench bracket, concrete ceramic tiles

Kč9.86

Historie ceny    

Nejnižší cena za posledních 30 dní byla Kč9.86

Tax included

The price shown is for 1 piece

Barva:
Total to be paid
Quantity
piece
At the supplier, delivery time (days): 3

The two-piece strut of the chimney bench bracket allows its installation on roof coverings made of concrete or ceramic tiles. The strut requires the use of additional mounting battens. In addition to struts, chimney sweep brackets are also required for proper installation of chimney sweep benches.

DB/DC type vertical footbridge for burnt concrete roof tiles

The two-piece strut of the chimney bridge support allows it to be installed on roof coverings made of concrete or ceramic tiles. The strut requires the use of additional mounting battens. In addition to the struts, chimney sweep brackets are required for proper installation of chimney benches.

Material

Galvanized steel strip by metallurgical process, the element is only available in painted finish.
The element is made using nailing technology.

Dimensions
  • Thickness: 3.8 +/- 0.2 mm
  • Width: 40 mm
  • Length: 583 mm

Stoupací plošina

Installation on all types of roofing

Our roof gutters can be installed on any type of roofing material. With our wide range of products, we have a product that can be installed on any type of roofing. No matter what material your roof is made of, we can provide the right solution for your needs.

Various lengths

The climbing platform is 250 mm wide, and its length depends on the option you choose. We offer the following lengths: 40 cm, 60 cm, 80 cm, 100 cm, 120 cm, 150 cm, 200 cm, 300 cm*.

Complete installation kits

For the convenience of our customers, we have introduced complete sets of roof communication - SMART packages - adapted to different types of roofing. For the convenience of our customers, we have introduced complete sets of roof communication - SMART packages - adapted to different types of roofing. These packages are also very attractively priced, which contributes to their wide availability.

Zinc coating

All components are manufactured from steel subjected to the zinc plating process. This is the most effective and durable way to protect steel from corrosion. During the tinning process, zinc atoms penetrate the outer layer of the steel, forming a surface alloy of iron and zinc, which forms a protective layer against corrosion. Depending on conditions, zinc coatings can last up to 100 years.

Powder coating

Powder coating is resistant to corrosion, chemicals, high temperatures and mechanical damage. Electrically charged powder paint particles are applied to the metal surface, which is then heated to 140-200°C, causing the powder to melt and polymerize. The advantages of powder coating include a smooth, crack- and stain-free surface, anti-corrosion properties, resistance to mechanical damage, thermal and chemical resistance, and environmental friendliness.

Wide range of colors

Two finishes are available - unpainted or powder-coated. As for powder coating, you can choose from nine beautiful standard colors. It is possible to paint the console in a non-standard (other than those listed in the table) color for an additional fee (lead time up to 10 days).

What is needed to install chimney caps?

For proper installation you will need the following items:

  • Climbing platform (from 40 to 300* cm)
  • Platform cradle
  • Platform strut (depending on the type of roofing)
  • Platform connector (if you need to connect a longer row of platforms)
  • Mounting screws to connect the individual components (you will receive them free of charge in the SMART package)
  • Screws for attaching the bench to the structure (not included)

*Length of 300 cm only on request




Protective coating - standard colors available:* * Color availability may vary depending on product.



RAL 8004

RAL 8017

RAL 8019
RAL 8012
RAL 3004
RAL 9005
RAL 7016
RAL 6020
Zinc

General principles of roof communication installation

Fastening the elements to each other and to the roof.

Roofcommunication brackets should be attached to the wooden roof structure with wood screws complying with PN-EN 14592+A1:2012. 8 mm x 60 mm screws for fixing the bracket to the roof can also be found in our store. The elements should be connected together using the screws (Ø 8 mm) included in the kit.

Chimney brackets are designed to create passageways across the roof slope. Chimney brackets must be attached to the roof at a distance of at least 80 cm. Note that this is the maximum distance allowed by the standard. More detailed information about the brackets and the number of fixing screws and their dimensions must be specified in the technical design.

Roof purlins complement the chimney bay system and are designed to create passageways along the roof slope. Roof purlins should be spaced alternately, allowing the roof to be walked on like a staircase. When designing the spacing between eaves, it is necessary to take into account the angle of the roof:

  • For roofs with a slope of up to 30° - install tiles in every second row of tiles, at a distance of 70 cm from each other.
  • For roofs with a slope of more than 30° - the battens should be installed in each row of tiles, every 35-40 cm.

Note: The above information is the result of collected information and our experience. The above information should not be considered as installation instructions. The use of roof communication should be in accordance with the technical design prepared for the building, taking into account the requirements of relevant standards and applicable technical and construction regulations. To add additional brackets to the kit, use the menu of individual items.

Chimney Sweep Bench Bracket - is designed for installation on tile roofs. It is a load-bearing element of the chimney batten or roof slope. The bracket is attached directly to the metal roofing through the batten to the rafters. Fastening screws ø8 must be selected so that their length significantly exceeds the thickness of the batten. To avoid breaking the roofing seal, the screws must be used with a sealing washer, and the mounting holes must be additionally sealed with asphalt, silicone or other sealant. Footbridge brackets should be installed at a distance of at least 800 mm and at every possible connection of chimney grilles with fasteners.